Description |
110-220V HI EMT; Lightly Used in Open Box
** RETAILS FOR $1951.90+TAX **
Item Type: Electromagnetic
Material: ABS
Applicable Parts: Abdomen, arms, shoulders, legs, buttocks
Interface Operation:Enter the mode selection interface after power on.PROTOCOL 1 is the automatic mode, PROTOCOL 2 is the manual modeAuto Model: Set the Strength, the range from 1 weak to strong?Strength?: Handle to adjust the strength, click [+], [-] of strength setting to adjust.Set strength before surgery, treatment starts from low strength and gradually increases according to patient tolerance.Working time setting. The default working time of the system is 15 minutes, click [+], [-] to adjust. The time range is adjustable from 1 ~ 30 minutes, and each part runs for about 15 minutes.Note: When the device is in pause, the parameters can be adjusted by clicking [+], [-].Manual Mode: Set the frequency f1 ~ f2. Click [+], [-] to adjust the output frequency, the range is as follows:?F1?: Strength range is 1HZweak to 100Hzstrong;?F2?: The strength range is 1HZweak to 100Hzstrong;Before operation, please set the frequency parameters according to the desired frequency. F1 frequency is working for 1 minute. F2 is working for 2 minutes. When working, F1 and F2 frequencies are cycled sequentially.Recommended Parameters: F1 is 20 ~ 50hz, F2 is 50~80Hz.Set strength, range from 1 weak to strong?Strength?: Handle strength, click [+], [-] to adjust. Set the Strength before surgery, treatment starts from low strength and gradually increases according to patient tolerance.Working Time Setting: The default working time of the system is 15 minutes, press [+] and [-] to adjust. Time range 1 ~ 30 minutes adjustable, each part runs about 15 minutesAfter Treatment:1. After use, users should promptly replenish water2. Do not overeat, eat and sleep reasonably3. After use must moisturize and sunscreen4. Avoid spicy and stimulating food5. Do not take a hot spring or within three days
Precautions:
1. Do not operate the head, face, eyes, temples, neck, near the carotid artery, thorax!!!
2. The treated person should not carry any metal objects.
3. You should not have the procedure on a full stomach. Take it at least 1 hour after a meal.
4. The operation site and probe should be dry and free of water.
5. Operating energy varies from person to person, gradually increasing from low energy!!!
6. The total working time of one day should not exceed 1.5 hours and one part should not exceed 0.5 hours.
7. Please do not put any electronic products or metal objects on the instrument during operation.
8. Please do not eat or drink during the operation
9. After the operation, try to eat 1 hour later drink more water and eat more food with high protein content.
Contraindications:
People with the following diseases cannot receive treatment :
1. The project should avoid menstruation, pregnancy, children, lactation.
2. With heart disease, hypertension, thyroid, malignant , renal failure, patients with cerebrovascular disease stroke, patients with major surgery, patients with diabetes, patients with heart disease such as arrhythmia, especially with pacemakers, epilepsy, muscle strain should be used with caution.
3. Use with caution in patients with metal or electronic implants metal contraceptive rings, pacemakers, cardiac defibrillators, neurostimulators, pumps, stents.
4. Use with caution in patients with thrombophlebitis, cerebrovascular disease stroke patients, brain
|